On 1/27/10 5:54 PM, Abel Alejandro wrote:
Hello,

Is it possible to know if there is a loopback on a T1 interface on a
Juniper?
If we need to verify if there is a loopback we activate a BERT test and
if the BERT synchronizes
then we know there is a loopback but I am wondering if there is an
easier way to verify this.

Regards,
Abel.

_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp


Hi Abel

You should easily be able to put a loop locally or remotely onto an interface with the following command ..

set interface t1-0/0/0 t1-options loopback local (or remote)

Then you should be able to run the BERT end to end with a tester.

There is a built in BERT test on the T1 interfaces, however I used this some years ago and found whilst it gives an indication of functionality, the actual results were a bit inconsistent on certain parameters. I believe the functionality of BERT was designed more for the T3 interfaces, the framers on the E1/T1 PIC's are not great for the BERT.

cheers
Sean