Hi! Some days ago one of our M10i's CFEB restarted with strange diagnostics - in the same second when BFD sessions get down there were following line in chassisd log:
Jul 2 14:03:08 CFEB 0 temperature is -60 degrees C, which is outside operating range (not sure if it appeared before or after BFD failures though, these lines found in different log files. BFD messages timestamped as 14:03:08.695, and no messages logged to remote syslog server since 14:01, so it's quite possible that CFEB failed first). Then there are lots of messages about CFEB not running/FPC restarts and so on messages, ends with CFEB restart and finally everything stabilised: Jul 2 14:03:12.663 2010 alarmd[1278]: Alarm set: CFEB color=RED, class=CHASSIS, reason=CFEB not online, the box is not forwarding Jul 2 14:03:12.672 2010 /kernel: rdp keepalive expired, connection dropped - src 0x00000001:1021 dest 0x00000002:2048 Jul 2 14:03:12.663 2010 chassisd[1277]: CHASSISD_SHUTDOWN_NOTICE: Shutdown reason: CFEB connection lost Jul 2 14:03:12.669 2010 craftd[1279]: Major alarm set, CFEB not online, the box is not forwarding There are no coredumps and no logs about reason of restart, just power-on notice in internal CFEB log: [0+00:00:00.255 LOG: Info] CSBR: Reset reason (0x4): Power On [0+00:00:00.255 LOG: Info] On-board NVRAM contains diagnostic information. and last logs in NVRAM is just CSBR: Reset reason (0x4): Power On Routing engine was not reset during this failure, and temperature readings shows just normal datacenter temperature of 22C/71F... Any ideas on what had happened ? _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp