Hi All,
I have 2 PPPoE servers on the same vlan. PPPoE server 1 is erx1410, MAC =
Unispher_40:08:a1 ,PPPoE Server 2 is erx1440,mac = Unispher_41:eb:42 .
See the PPPoE log below,I am wondering why the ERX1440 send the PADR to PCs
and not ERX1410? Does the Junose support "delayNumber of seconds that the
PPPoE underlying interface waits after receiving a PADI packet from the client
before sending a PADO packet in response."?
Anybody know how to implement 2 PPPoE servers? one as primary, one as backup?
144 109.606151 Intel_83:4f:b3 Broadcast PPPoED Active
Discovery Initiation (PADI)
145 109.606740 Unispher_41:eb:42 Intel_83:4f:b3 PPPoED Active
Discovery Offer (PADO) AC-Name='ERX1440-LNS2-erx2'
146 109.606779 Intel_83:4f:b3 Unispher_41:eb:42 PPPoED Active
Discovery Request (PADR)
147 109.609564 Unispher_40:08:a1 Intel_83:4f:b3 PPPoED Active
Discovery Offer (PADO) AC-Name='ERX1410-LNS1-erx1'
148 109.708460 Unispher_41:eb:42 Intel_83:4f:b3 PPPoED Active
Discovery Session-confirmation (PADS)
149 109.737316 Intel_83:4f:b3 Unispher_41:eb:42 PPP LCP
Configuration Request
150 109.809762 Unispher_41:eb:42 Intel_83:4f:b3 PPP LCP
Configuration Request
151 109.809865 Unispher_41:eb:42 Intel_83:4f:b3 PPP LCP
Configuration Reject
152 109.824677 Intel_83:4f:b3 Unispher_41:eb:42 PPP LCP
Configuration Ack
153 109.829249 Intel_83:4f:b3 Unispher_41:eb:42 PPP LCP
Configuration Request
154 109.829903 Unispher_41:eb:42 Intel_83:4f:b3 PPP LCP
Configuration Ack
155 109.845212 Intel_83:4f:b3 Unispher_41:eb:42 PPP LCP
Identification
156 109.845315 Intel_83:4f:b3 Unispher_41:eb:42 PPP LCP
Identification
157 109.845546 Intel_83:4f:b3 Unispher_41:eb:42 PPP PAP
Authenticate-Request
158 110.008150 Unispher_41:eb:42 Intel_83:4f:b3 PPP PAP
Authenticate-Ack
159 110.015315 Intel_83:4f:b3 Unispher_41:eb:42 PPP CCP
Configuration Request
160 110.015464 Intel_83:4f:b3 Unispher_41:eb:42 PPP IPCP
Configuration Request
161 110.015739 Unispher_41:eb:42 Intel_83:4f:b3 PPP LCP
Protocol Reject
162 110.016237 Unispher_41:eb:42 Intel_83:4f:b3 PPP IPCP
Configuration Reject
163 110.025478 Intel_83:4f:b3 Unispher_41:eb:42 PPP IPCP
Configuration Request
164 110.025938 Unispher_41:eb:42 Intel_83:4f:b3 PPP IPCP
Configuration Nak
165 110.040954 Intel_83:4f:b3 Unispher_41:eb:42 PPP IPCP
Configuration Request
166 110.041395 Unispher_41:eb:42 Intel_83:4f:b3 PPP IPCP
Configuration Ack
167 110.209895 Unispher_41:eb:42 Intel_83:4f:b3 PPP IPCP
Configuration Request
168 110.259887 Intel_83:4f:b3 Unispher_41:eb:42 PPP IPCP
Configuration Ack
delayNumber of seconds that the PPPoE underlying interface waits after
receiving a PADI packet from the client before sending a PADO packet in
response. In networks with mesh topologies, you might want to designate a
primary PPPoE server and a backup PPPoE server for handling a particular
service request. In such a scenario, you can configure a delay for the
associated service name tag on the backup PPPoE server to allow sufficient time
for the primary PPPoE server to respond to the client with a PADO packet. If
the primary server does not send the PADO packet within the delay period
configured on the backup server, then the backup server sends the PADO packet
after the delay period expires.
http://www.juniper.net/techpubs/en_US/junos10.1/information-products/topic-collections/config-guide-network-interfaces/topic-40403.html
http://www.juniper.fr/techpubs/software/erx/erx51x/swconfig-link/html/pppoe-config9.html
Thanks
Terry
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp