Once upon a time, Paul Stewart <[email protected]> said: > I have to agree here - having the monitoring software "rediscover" where the > ifindex for an interface is after a reboot isn't ideal in my opinion.....
It is a case you have to handle anyway. What if you upgrade REs, or you have REs die and you have to replace them? The index values will change then anyway. How do you handle that? Do you manually update your monitoring configs? All the information is provided in SNMP, you just need to use it. My monitoring and management scripts walk and cache ifDescr to find the desired interface and then use the ifIndex. Every time they fetch something for an interface, they include the ifDescr. If the ifDescr still matches, that's all it takes. If it is different, the scripts discards the ifDescr cache and re-walks the ifDescr tree. This is one of the reasons I switched from MRTG to Cricket 10+ years ago; I configure Cricket to graph "so-0/2/1", not "17". Who knows what "17" is; "so-0/2/1" is pretty obvious. -- Chris Adams <[email protected]> Systems and Network Administrator - HiWAAY Internet Services I don't speak for anybody but myself - that's enough trouble. _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp