Hi Chris Maybe you could tie the tunnels to redundant services interfaces. (RSP's)
http://www.juniper.net/techpubs/software/junos/junos94/swconfig-services/configuring-as-or-multiservices-pic-redundancy.html Cheers //KJ On 17 August 2010 01:12, Chris Evans <[email protected]> wrote: > Looking for input from folks as I am not able to find an answer via > google.. > > I have a question about tunnel interfaces. My question is mainly how do you > have failover/backup hardware within a platform? Prime example is on an MX > or M series. When one creates a tunnel interface you have to specify the > FPC/PIC tied to hardware (gr-5/1/0 for example). If this hardware fails > there isn't a way for it to failover. As I can specify the > source/destination IP within the tunnel interface that piece isn't tied to > hardware. Is there a way to create a redundancy group? > > I come from a Cisco world and this is something I'm challenged with. Tunnel > interfaces on Cisco devices are completely virtual and isn't tied to any > specific piece of hardware, thus modules can fail and the tunnel still > functions. > > > Thanks! > > Chris > _______________________________________________ > juniper-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/juniper-nsp > -- //kjwilki _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp