Hi,
We have seen that, with 3rd party SFPs. After a lot of testing, we found one
that works. You could off course just purchase the original ones.
FPC slot 0, PIC slot 0 information:
Type 24x 100 Base-FX/1000 Base-X Builtin
State Online
Uptime 59 days, 52 minutes, 35 seconds
PIC port information:
Fiber Xcvr vendor
Port Cable type type Xcvr vendor part number Wavelength
22 GIGE 1000T n/a Methode Elec. SP7041-M1-JN n/a
23 GIGE 1000T n/a Methode Elec. SP7041-M1-JN n/a
Kind Regards,
Peter Krupl
Siminn Danmark A/S
> -----Original Message-----
> From: [email protected] [mailto:juniper-nsp-
> [email protected]] On Behalf Of Martin T
> Sent: 05. November, 2010 01:32
> To: [email protected]
> Subject: [j-nsp] 1000BASE-T SFP sets interface status "up" once inserted into
> EX4200-24F
>
> I have few ProLabs GLC-T-C 1000BASE-T SFP's. If I insert this SFP into
> EX4200-24F switch, both Admin and Link status are immediately "up". Admin
> status should be "up" by default, but I find it odd, that Link status stays
> "up" as well even if there is no cable connected to the SFP.
>
> When I insert the SFP, "show log messages" shows following error/warning:
> Oct 9 17:42:36 chas[727]: IFCM: no handler for command subtype 226
>
> JUNOS version is 10.3R1.9 and switch model is EX4200-24F.
>
> Any ideas, what might cause such odd behavior, where interface Link status
> is set "up" even if there is no cable connected to the port?
> _______________________________________________
> juniper-nsp mailing list [email protected]
> https://puck.nether.net/mailman/listinfo/juniper-nsp
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp