Not in the router but you can use http://code.google.com/p/samplicator/
On Tue, Aug 9, 2011 at 20:14, Emmanuel Halbwachs < [email protected]> wrote: > Hello, > > I would like to run more than one collector software on the same > host. The use case is: > > - benchmarking different tools with the same netflow data > - running simultaneously two tools with complementary features > > The idea was to send the same netflow data to different UDP ports, but > on our MX80 (10.4R3.4), it seems that only one 'port' stanza is > permitted per 'flow-server' container. > > [edit forwarding-options sampling family inet output] > flow-server 10.0.0.20 { > port [ 2055 2056 2057 ]; <-- NOT POSSIBLE > } > > Using one IP per software and using IP alias on the collector host > works but is, well, not that elegant and not that convenient: > > set forwarding-options sampling family inet output flow-server 10.0.0.20 > port 2055 > set forwarding-options sampling family inet output flow-server 10.0.0.21 > port 2056 > set forwarding-options sampling family inet output flow-server 10.0.0.22 > port 2057 > > If someone have some clues. > > Thanks, > > -- > Emmanuel Halbwachs Observatoire de Paris-Meudon > Resp. Réseau/Sécurité 5 Place Jules Janssen > tel : +33 1 45 07 75 54 F 92195 MEUDON CEDEX > fax : +33 1 45 07 01 89 véhicules : 11 av. Marcellin Berthelot > _______________________________________________ > juniper-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/juniper-nsp > _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp