Short answer: You can mix the VCP ports, but you cannot LAG them.

You can have an EX4200 using the back-of-chassis 32Gbps VCP-dedicated ports at 
the same time using your front-of-chassis XFP or SFP+ also as VCP-configured 
ports. It's also nice to know that even while doing this, you can use remaining 
front-of-chassis optical ports as configured inet or switched ports.

I've also had success forming a VC between EX4200s' SFP+ VCP ports through a 
DWDM network over 30 miles away, though I wouldn't recommend this for a 
permanent reliable solution.

Paul Zugnoni

On Jan 3, 2012, at 09:36 , Dave Peters wrote:

Hi all--

This is simple, but I can't find definitive proof online . . .

Can I set up a Juniper EX series virtual chassis using a high-speed backbone on 
one floor of a building and then connect that VC to another switch (or two) via 
link-aggregation on the SFP ports?

I'm not sure you can mix the VC connections, is all.  Can I use both the 
stacking backbone on one floor and the SFP links on another floor in the same 
virtual chassis?

Thanks much.

--
Dave Peters