HI,
yep we have same recommendation from Juniper.
New problematic feature can be disabled on FPC level by:
set ichip selfping disable
But it must be entered to every singe FPC (based on ichip ) if router or
fpc is rebooted.
Regards
Tomas
Dne 23-Jan-12 16:20, OBrien, Will napsal(a):
I opened a TAC case on this as my production boxes are on 8.5 now.
I'm told that this does affect 10.4r8.5.
It's been recommended to go to r7.5 for now if I want to stick with 10.4.
Thoughts?
On Jan 23, 2012, at 9:16 AM, bas wrote:
Hi,
On Mon, Jan 23, 2012 at 3:57 PM, Daniel Hilj<[email protected]> wrote:
This is a critical defect which effects only DPC, and not MPC.
Customers with DPC is discourage using Junos 10.4R8, 10.4S8(A), and
10.4S8(B).
Strange, I see:
---
SYNOPSIS MPC may restart with backtrace in ia_wpkt_next() routine
RELEASE NOTE Introduced in Junos software version 10.4R8, a DPC may
restart unexpectedly [snip]
---
So the Synopsis mentions MPC..
Bas