HI,

yep we have same recommendation from Juniper.
New problematic feature can be disabled on FPC level by:

set ichip selfping disable

But it must be entered to every singe FPC (based on ichip ) if router or fpc is rebooted.

Regards

Tomas



Dne 23-Jan-12 16:20, OBrien, Will napsal(a):
I opened a TAC case on this as my production boxes are on 8.5 now.
I'm told that this does affect 10.4r8.5.
It's been recommended to go to r7.5 for now if I want to stick with 10.4.

Thoughts?


On Jan 23, 2012, at 9:16 AM, bas wrote:

Hi,

On Mon, Jan 23, 2012 at 3:57 PM, Daniel Hilj<[email protected]>  wrote:

This is a critical defect which effects only DPC, and not MPC.
Customers with DPC is discourage using Junos 10.4R8, 10.4S8(A), and
10.4S8(B).
Strange, I see:

---
SYNOPSIS        MPC may restart with backtrace in ia_wpkt_next() routine
RELEASE NOTE    Introduced in Junos software version 10.4R8, a DPC may
restart unexpectedly [snip]
---

So the Synopsis mentions MPC..

Bas
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp
Will O'Brien
University of Missouri, DoIT DNPS
Network Systems Analyst - Redacted

[email protected]




_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to