Thanks for all the input. I'm beginning to get an understanding here. So, the vlan sub-int on the MX could be a MEP. The port on the switch where the customer connects can't be a MEP. We'll have to assume that I have no administrative control whatsoever over the customer router. I can't even insure that it's a router. Could be an ASA, could be a server, could be a router, just random device that can route packets to some extent. I would like to vlan connections back up to the MX for layer-3 configurations. My problem is that if the customer facing port on the switch goes down, it won't take down the layer-3 int on the MX, thus sending packets to nowhere.
The IRB instance sounds interesting, I'll try playing with that as well. Thanks for the input all, much appreciated! --chip On Fri, Apr 20, 2012 at 4:57 PM, Keegan Holley <[email protected]> wrote: > CFM wouldn't monitor a link with no MEP on the other end of it. So you > can't have a router a switch and then a link from the switch to a customer > and monitor a link to a customer where the customer isn't running CFM on > their equipment. > > 2012/4/20 Humair Ali <[email protected]> >> >> Actually CFM would be appropriate with what Chip is trying to achieve, >> >> CFM monitor a maintenance session end to end and works a vlan or link >> level. >> >> Why not monitor Cust Rtr interface to MX1 accross the bridge network via >> CFM and have an action profile assign to it ? >> >> or monitor Cust Rtr 1 to remote end Cust Rtr 2 CFM , since usually you >> would want to use CFM to guarantee a service. >> >> >> On 20 April 2012 18:20, Keegan Holley <[email protected]> wrote: >>> >>> CFM just performs a continuity check so I'm not sure it will help you >>> here. In other words it just checks if the CFM instance on the switch >>> can >>> talk to the CFM instance on the router. If I understand your question >>> correctly you're trying to verify an access point leading to a customer >>> and >>> not your MX. If there is only one access port per VLAN interface can you >>> move it down to the switch? >>> >>> >>> 2012/4/20 chip <[email protected]> >>> >>> > Hi folks, >>> > >>> > I'm trying to figure out if I can create a >>> > connectivity-fault-management instance between a vlan sub interface on >>> > an MX and the access port in the same vlan on a down stream switch. >>> > Possibly this will help: http://imgur.com/MMrZm >>> > >>> > Ultimately my goal is to detect an outage on the access port and take >>> > down the layer-3 interface on the MX so I won't blackhole traffic. >>> > Since that interface won't go down if the access port on the >>> > downstream switch does. Or maybe there's a better solution. Either >>> > way, if someone has this setup and can supply some example configs I >>> > would be ever so grateful. I can't quite seem to work it out. >>> > >>> > Thanks all! >>> > >>> > --chip >>> > >>> > -- >>> > Just my $.02, your mileage may vary, batteries not included, etc.... >>> > >>> > _______________________________________________ >>> > juniper-nsp mailing list [email protected] >>> > https://puck.nether.net/mailman/listinfo/juniper-nsp >>> > >>> > >>> _______________________________________________ >>> juniper-nsp mailing list [email protected] >>> https://puck.nether.net/mailman/listinfo/juniper-nsp >> >> >> >> >> -- >> Humair >> > -- Just my $.02, your mileage may vary, batteries not included, etc.... _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp