* Wayne Tucker

> 2.) Configure xe-0/0/0 in area 1 of both MXs as a secondary interface.
>  That will allow them to exchange the LSDB for that area even when the
> downlink to the EX is down.  There are other reasons that you'd
> probably want that, anyhow.

Sweet. I had no idea that a single interface could participate in
several areas. This solution works very well - thank you!

Best regards,
-- 
Tore Anderson
Redpill Linpro AS - http://www.redpill-linpro.com/
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to