I always configure my VC-EX switches all with priority 255. If they have different priorities you can't manually failover and as mentioned other weird stuff happens.
Luca -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Eugeniu Patrascu Sent: Thursday, 4 October 2012 3:46 AM To: Muruganandham M Cc: [email protected] Subject: Re: [j-nsp] GRES on EX-Virtual chassis On Wed, Oct 3, 2012 at 8:51 AM, Muruganandham M <[email protected]> wrote: > Hello, > > I am referring the following link. > > http://www.juniper.net/techpubs/en_US/junos10.3/topics/task/configurat > ion/virtual-chassis-gres-cli.html > > Is it mandatory to configure the mastership-priority to 255 to enable > GRES on the VC ? IIRC, when you have a two switch EX4200 VC, it's mandatory to set the priority manually to 255 on both members, otherwise weird stuff might happen. I run a pair like this and it's been stable for more than a year now. Eugeniu _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp