Can anybody give me an idea regarding typical failover times if the master in a two switch pair were to die? The quickest I've seen in my testing with EX3300's is 45 seconds, just for L2 forwarding to continue working, no routing. All the ports drop link as well on the secondary switch while things switch over. I can have my laptop connected to the secondary switch, passing traffic up an uplink on the secondary, and if the master dies it creates a 45 second interruption.
Normal? Morgan On Sun, Oct 28, 2012 at 2:24 PM, Giuliano Medalha <[email protected]>wrote: > Robert, > > It was released by juniper one or two weeks ago I think. > > Take a look: > > https://www.juniper.net/us/en/products-services/routing/mx-series/mx2000/ > > MX2010 > MX2020 > > > https://www.juniper.net/us/en/products-services/routing/mx-series/mx2000/#specifications > > But I really don't know if it will support virtual chassis without JCS. > > Att, > > Giuliano > > > > On Sun, Oct 28, 2012 at 3:47 PM, Robert Hass <[email protected]> wrote: > >> On Fri, Oct 26, 2012 at 11:44 PM, Giuliano Medalha >> <[email protected]> wrote: >> > Considering the MX family (240, 480 and 960 with TRIO 3D) and the new >> MX-L >> >> Hi >> What is new MX-L - can you write a little mort ? MX80 successor ? >> >> Rob >> > > _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp