Hi,
On my EX4200 running version 12.3R1.7 is see the following alarms in the
logging:
Mar 21 08:46:46 <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP
trap generated: Power Supply Removed (jnxContentsContainerIndex 2,
jnxContentsL1Index 1, jnxContentsL2Index 3, jnxContentsL3Index 0,
jnxContentsDescr Power Supply: Power Supply 2 @ 0/2/*, jnxOperatingState/Temp 1)
... 41 more times same type of alarms ...
Mar 21 08:46:46 <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP
trap generated: Fan/Blower Removed (jnxContentsContainerIndex 4,
jnxContentsL1Index 2, jnxContentsL2Index 1, jnxContentsL3Index 1,
jnxContentsDescr FAN: Fan 1 @ 1/0/0, jnxOperatingState/Temp 1)
Mar 21 08:46:46 <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP
trap generated: Power Supply Removed (jnxContentsContainerIndex 2,
jnxContentsL1Index 8, jnxContentsL2Index 1, jnxContentsL3Index 0,
jnxContentsDescr Power Supply: Power Supply 0 @ 7/0/*, jnxOperatingState/Temp 1)
Mar 21 08:46:46 <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP
trap generated: Fan/Blower Removed (jnxContentsContainerIndex 4,
jnxContentsL1Index 2, jnxContentsL2Index 1, jnxContentsL3Index 2,
jnxContentsDescr FAN: Fan 2 @ 1/0/1, jnxOperatingState/Temp 1)
Mar 21 08:46:46 <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP
trap generated: Power Supply Removed (jnxContentsContainerIndex 2,
jnxContentsL1Index 8, jnxContentsL2Index 3, jnxContentsL3Index 0,
jnxContentsDescr Power Supply: Power Supply 2 @ 7/2/*, jnxOperatingState/Temp 1)
... 32 more times same type of alarms ...
The environment is OK and also no alarms are active.
petert@mnz-bascule03-sw01> show chassis environment
Class Item Status Measurement
Power FPC 0 Power Supply 0 OK
FPC 0 Power Supply 1 OK
Temp FPC 0 CPU OK 27 degrees C / 80 degrees F
FPC 0 EX-PFE1 OK 43 degrees C / 109 degrees F
FPC 0 EX-PFE2 OK 45 degrees C / 113 degrees F
FPC 0 GEPHY Front Left OK 27 degrees C / 80 degrees F
FPC 0 GEPHY Front Right OK 31 degrees C / 87 degrees F
FPC 0 Uplink Conn OK 32 degrees C / 89 degrees F
Fans FPC 0 Fan 1 OK Spinning at normal speed
FPC 0 Fan 2 OK Spinning at normal speed
FPC 0 Fan 3 OK Spinning at normal speed
{master:0}
petert@mnz-bascule03-sw01> show chassis alarms
No alarms currently active
Is this a bug of did I configure something incorrect?
With kind regards,
Peter Tavenier