Hi, 

On my EX4200 running version 12.3R1.7 is see the following alarms in the 
logging: 

Mar 21 08:46:46  <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP 
trap generated: Power Supply Removed (jnxContentsContainerIndex 2, 
jnxContentsL1Index 1, jnxContentsL2Index 3, jnxContentsL3Index 0, 
jnxContentsDescr Power Supply: Power Supply 2 @ 0/2/*, jnxOperatingState/Temp 1)
... 41 more times same type of alarms ...
Mar 21 08:46:46  <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP 
trap generated: Fan/Blower Removed (jnxContentsContainerIndex 4, 
jnxContentsL1Index 2, jnxContentsL2Index 1, jnxContentsL3Index 1, 
jnxContentsDescr FAN: Fan 1 @ 1/0/0, jnxOperatingState/Temp 1)
Mar 21 08:46:46  <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP 
trap generated: Power Supply Removed (jnxContentsContainerIndex 2, 
jnxContentsL1Index 8, jnxContentsL2Index 1, jnxContentsL3Index 0, 
jnxContentsDescr Power Supply: Power Supply 0 @ 7/0/*, jnxOperatingState/Temp 1)
Mar 21 08:46:46  <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP 
trap generated: Fan/Blower Removed (jnxContentsContainerIndex 4, 
jnxContentsL1Index 2, jnxContentsL2Index 1, jnxContentsL3Index 2, 
jnxContentsDescr FAN: Fan 2 @ 1/0/1, jnxOperatingState/Temp 1)
Mar 21 08:46:46  <hostname> chassisd[1290]: %DAEMON-5-CHASSISD_SNMP_TRAP6: SNMP 
trap generated: Power Supply Removed (jnxContentsContainerIndex 2, 
jnxContentsL1Index 8, jnxContentsL2Index 3, jnxContentsL3Index 0, 
jnxContentsDescr Power Supply: Power Supply 2 @ 7/2/*, jnxOperatingState/Temp 1)
... 32 more times same type of alarms ...

The environment is OK and also no alarms are active. 

petert@mnz-bascule03-sw01> show chassis environment
Class Item                           Status     Measurement
Power FPC 0 Power Supply 0           OK
      FPC 0 Power Supply 1           OK
Temp  FPC 0 CPU                      OK         27 degrees C / 80 degrees F
      FPC 0 EX-PFE1                  OK         43 degrees C / 109 degrees F
      FPC 0 EX-PFE2                  OK         45 degrees C / 113 degrees F
      FPC 0 GEPHY Front Left         OK         27 degrees C / 80 degrees F
      FPC 0 GEPHY Front Right        OK         31 degrees C / 87 degrees F
      FPC 0 Uplink Conn              OK         32 degrees C / 89 degrees F
Fans  FPC 0 Fan 1                    OK         Spinning at normal speed
      FPC 0 Fan 2                    OK         Spinning at normal speed
      FPC 0 Fan 3                    OK         Spinning at normal speed

{master:0}
petert@mnz-bascule03-sw01> show chassis alarms
No alarms currently active

Is this a bug of did I configure something incorrect? 

With kind regards,

Peter Tavenier