Hi, On Tue, May 28, 2013 at 05:00:25PM +0400, Nick Kritsky wrote: > One additional question: do you use the same approach (description on both > levels) for switch-ports inside DC or in campus network? Assuming that we > talk about regular access level ports that only have unit 0 with "family > eth" on them. I mean - in this case, descriptions on unit-level and > interface-level will be pretty much the same?
Given that most management applications discover the SNMP interface instance with the IP address attached to it and display the interface description of that ifIndex only, I usually only use the logical interface (unit) description. Unless with multi-unit interfaces, where I document the physical remote side in physical interface level description, and the service description on the unit. Same goes for switches - using the unit-level description generally, with addition physical interface description for trunk remote system/port documentation. Best regards, Daniel -- CLUE-RIPE -- Jabber: [email protected] -- dr@IRCnet -- PGP: 0xA85C8AA0 _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp