Hi, the SCM will only allow you to use a secondary control link on the srx3600. Juniper sales ing said that they are not planning to add support for a second RE on the srx3000 family. if you don't have the SCM the second control port will be/stay disable. Hope it helps Santiago.
> On 16 Dec 2013, at 21:26, "OBrien, Will" <[email protected]> wrote: > > Second REs don't really do anything on SRX... yet. > > On the 5800s, I had to add them in order to bring up a secondary control > link. The only thing they do is init the control plane on the chassis for > that link to come up. > I believe it's an artifact from stealing the MX chassis. I don't think it > does anything for you on the 3600, since that's a different chassis > architecture altogether. > > Will > > >> On Dec 16, 2013, at 3:07 PM, Morgan McLean wrote: >> >> Hi all, >> >> Looking into installing the SCM module into a couple of SRX3600's I have in >> production. Notice the diagram from juniper says slot RE1 for SCM. Do they >> support running another RE? Just curious if anybody does this, if its worth >> it or if its even possible. >> >> -- >> Thanks, >> Morgan >> _______________________________________________ >> juniper-nsp mailing list [email protected] >> https://puck.nether.net/mailman/listinfo/juniper-nsp > > > _______________________________________________ > juniper-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/juniper-nsp _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp