On 6/23/2014 午後 05:07, Joerg Staedele wrote:
Hi there,

i am asking myself if it really makes sense to have a redundant RE setup in M 
and MX-series. Maybe some of you could tell me if they had a scenario where it 
really helped to prevent an outage.

I am not talking about ISSU/NSSU feature where it is needed.

We didn't have a failed RE since years so for now all our redundant setups seem 
not make any sense at all.

What are your experiences?

Regards,
  Joerg


_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp
I haven't seen the REs die due to any direct faults either, ever.

However, they do exhibit issues with fw corruption and the like on abrupt power loss, and co.

In my opinion, you do not get redundant REs for it to be immediately useful, you keep them for when s* really hits the fan.

Similar analogy to A+B power / network.
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to