On (2014-07-15 11:25 +0400), [email protected] wrote: Hi,
> Jul 15 09:00:38 tfeb0 LUCHIP(0) PPE_15 Errors sync xtxn error > Jul 15 09:00:38 tfeb0 PPE Sync XTXN Err Trap: Count 50, PC 617c, 0x617c: > flow_age_read_active_timestamp 0x617c: flow_age_ipv4 Each LUCHIP has 16 PPE, lookup tasks are sprayed to PPEs to distribute work, each PPE has 20 contexts, so that PPE can work even when doing I/O wait. You can get more data about PPE 15 from 'show luchip 0 ppe 15 ...' maybe 'trap_info', after logging to the TFEB via 'start shell pfe network tfeb0 ' > What is it? I'd guess like Abhi that it's related to IPFIX. I don't think it has anything to do with linecard synchronization like Iftikhar suggested, PPE does not really experience or talk to linecard. There is absolute limit how long PPE can work, maybe 'sync xtxn' implies PPE worked longer than allowed? It does not look too bad to me really, if it's failing to read flows active timestamp, does not seem the reprecussions would be too dramatic. -- ++ytti _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp

