Hello,
I think we are missing some important details here.
AFAIK, in order to detect MAC moves, the port must be in a
bridge-domain/VPLS instance.
So Your MX480 ae0 must be a L2/"bridged" port, not a L3/routed one.
So the question would be - are there any other ports on this MX480 in
same bridge-domain(BD)/VPLS instance?
If not, but You have an IRB interface in this BD, does it have "IS-IS
passive" enabled by any chance? "IS-IS passive" does not actually stop
ES-IS PDUs being sent out, so these pesky ES-IS mcast frames could be
the ones which looped.
Additionally, MAC move limiting is not supported on EX4550 VC and in
mixed EX4200-4500/4550 VC so if Your EX4200 VC is actually a mixed
EX4200-4500/4550 VC there is no chance getting it stopped on EX.
https://www.juniper.net/techpubs/en_US/release-independent/junos/topics/concept/ex-series-software-features-overview-vc.html#port-security-features-by-platform-table
Thanks
Alex
On 07/11/2014 14:18, Jeff Meyers wrote:
Hello everybody,
I'm writing to this list because I can't seem to find the reason for
what we saw twice meanwhile. Here is the setup:
Juniper MX480 no RSTP
||
ae0
||
Juniper EX4550 VC RSTP bridge id 0
||
ae0
||
Juniper EX4200 VC RSTP bridge id 16k
|
ProCurve 2824 RSTP bridge id 32k
|
Windows Host
So the router itself is not part of the Spanning-Tree, everything
below is. On the Windows host, the customer is running ESXi with just
one uplink towards the HP ProCurve switch so there is not even a real
danger for a physical loop. Now: on the host are two VMs running. Each
of them has a virtual NIC which is bridged to the physical one of the
host. Because of a mistake, the customer accidentally bridged his two
VMs together as well which caused a loop inside the Host. So far, so
good.
The trouble begins at this point because immediately we saw partial
network outages resulting in router messages like this:
Nov 7 14:30:47 cr0 l2ald[2545]: L2ALD_MAC_MOVE_NOTIFICATION: MAC
Moves detected in the system
This message repeated over and over and the ARP counter decreased
continueously. Host flapped and vanished for seconds or minutes and
internal smokeping measured a lot of loss.
The HP ProCurve logged only excessive broadcast for the customer port
and that's it. Spanning-Tree didn't recognize anything. The same
applies to the EX4200 VC and the EX4550 VC: nothing was detected by
the loop preventing procotol and it was only a lucky shot, that we
knew where to look because the customer called by phone and told us,
what he did.
The question is: how can that be and what can I do?
On the EX-series switches, each downlink port is configured with
set protocols rstp interface ge-0/0/0 no-root-port
storm-control is enabled on all ports with 85% (but none was
detected). There is no special configuration on the ProCurve besides
the general RSTP activation (which is set to RSTP and not STP).
So can anybody help with that? I am really stuck here.. :(
Thanks in advance,
Jeff
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp