Just as a thought, do both systems have time synchronized with something
like ntp?
I've found that it helps to use the same timezone on the system hosting
WANGuard as well as the routers (You should technically be using UTC anyway)
On 1/26/2015 午前 06:34, John Brown wrote:
Hi,
I'm looking for advise on configuring our MX480 (Junos 12.3R4.6) to support
IPFIX flows for Andrisoft's WanGuard flow based tools. They only have
samples for M series and that C company.
I'm getting some errors on the Andrisoft console that make me wonder if I
have things set right.
The MX is feeding multiple 10Gig links and a pile of 1 Gig links, both IPv4
and IPv6
Many thanks for pointers and help....
here is the error I get on the Andrisoft console
Wrong flow timeout settings! Received flow from 391 seconds in the past! 16
flows discarded
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp