request chassis routing-engine power-off other-routing-engine etc..etc..? 
(....something along those lines)

I recall I just did this last week on an MX480 (someone put the same fxp0 IPs 
on both REs..) so I shut one RE down from the other RE with some type of 'power 
off' command to avoid ip-to-mac flipping every few seconds while I fixed it. 
Not a "reboot" command, but an actual "hey chasissd -- kill the power to this 
thing" command.

Steinar's command re: kill all power to CB0 should do the same thing, but takes 
down the fabric board as well.

- Ck.


On 19/08/2015, at 6:42 PM, Tom Eichhorn <[email protected]> wrote:

> Hi,
> 
> I was just wondering, is there a way to force reset a routing engine
> from the other in the same chassis?
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp