Hi,

Just to update everyone on this, this is still repeating on the latest recommended release (which as of now is 14.1-X53-D30)

Dec 11 01:46:16 ar-0.csit.lax.queryfoundry.net sflowd[1340]: ipc_pipe_read cannot exceed pipe size 1500 bytes Dec 11 01:46:16 ar-0.csit.lax.queryfoundry.net pfex: Sflow client: Socket to sflowd closed Dec 11 01:46:16 ar-0.csit.lax.queryfoundry.net pfex: pfe_bcm sflow ipc error 0 Dec 11 01:46:37 ar-0.csit.lax.queryfoundry.net last message repeated 309 times Dec 11 01:46:37 ar-0.csit.lax.queryfoundry.net sflowd[1340]: ipc_pipe_read cannot exceed pipe size 1500 bytes Dec 11 01:46:37 ar-0.csit.lax.queryfoundry.net pfex: Sflow client: Socket to sflowd closed Dec 11 01:46:37 ar-0.csit.lax.queryfoundry.net pfex: pfe_bcm sflow ipc error 0
.
[email protected]# run show version
fpc0:
--------------------------------------------------------------------------
Hostname: ar-0.csit.lax.queryfoundry.net
Model: ex4300-48t
Junos: 14.1X53-D30.3
JUNOS EX  Software Suite [14.1X53-D30.3]
JUNOS FIPS mode utilities [14.1X53-D30.3]
JUNOS Online Documentation [14.1X53-D30.3]
JUNOS EX 4300 Software Suite [14.1X53-D30.3]
JUNOS Web Management Platform Package [14.1X53-D30.3]
JUNOS py-base-powerpc [14.1X53-D30.3]

fpc1:
--------------------------------------------------------------------------
Hostname: ar-0.csit.lax.queryfoundry.net
Model: ex4300-48t
Junos: 14.1X53-D30.3
JUNOS EX  Software Suite [14.1X53-D30.3]
JUNOS FIPS mode utilities [14.1X53-D30.3]
JUNOS Online Documentation [14.1X53-D30.3]
JUNOS EX 4300 Software Suite [14.1X53-D30.3]
JUNOS Web Management Platform Package [14.1X53-D30.3]
JUNOS py-base-powerpc [14.1X53-D30.3]




On 10/31/2015 05:33 AM, Adam Rothschild wrote:
Hi Paul,

Was just curious -- were you able to identify a fix for this?

About to open a JTAC case on same. :)

Best,
-a

On Wed, Apr 8, 2015 at 10:13 PM, Paul S. <[email protected]> wrote:
Hi guys,

Picked up a few EX4300s to use as L3 switches, so far they've worked well.

Deployed a few new ones today, upgraded them to the latest recommended by
JTAC and set them up in a 2 member VC. I also turned on graceful switchover,
commit synchronization and non-stop-routing.

fpc0:
--------------------------------------------------------------------------

Model: ex4300-48p
JUNOS EX  Software Suite [13.2X51-D30.4]


fpc1:
--------------------------------------------------------------------------
Model: ex4300-48p
JUNOS EX  Software Suite [13.2X51-D30.4]


Then, I tried to turn sflow on. It works, sends samples to the collectors,
but is spamming the logs with this.

Apr  9 02:00:36  ar-0 pfex: pfe_bcm sflow ipc error 0
Apr  9 02:00:50  ar-0 last message repeated 22 times
Apr  9 02:02:50  ar-0 last message repeated 183 times

I'm not exactly sure of what this means, anyone ever see it around before
and can it be ignored or should I turn sflow off for now?

Thanks.
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to