While it was not really advisable to run fabric link over a stack of
switches, (and not to have cluster stretched over datacenter) I have
setup many srx cluster in a similar way.
Two points to check :
- obviously a separate single vlan by fabric link (untag on the srx
side, even if it may work tagged).
- jumbo frame (at least 9000), because fabric link use special frame
(and long one). If the mtu remains at 1500, strange thing may happen.
- no stp/whatever on the ports
Regards,
--
Raphael Mazelier.
Le 13/01/16 17:04, james list a écrit :
Hi experts,
a customer of mine has implemented an SRX cluster HE(1400) over a L2 (vlan)
infrastructure and is having sometime problems on the dual FAB links, which
trigger basically a split brain.
The cluster is geographically stretched and in one site the customer has
Cisco Nexus 5k and on the other has Extreme switches.
I’m not having a lot of info by the customer, I can only see that they have
configured PVSTP on Cisco side and no STP protocol on Extreme side.
Has anyone experienced problems in these kind of scenario ?
I’m aware of the Juniper prerequisites stated here:
http://kb.juniper.net/library/CUSTOMERSERVICE/GLOBAL_JTAC/NT21/LAHAAppNotev4.pdf
I’m looking for real experience and comments, what to check, any help, etc.
Cheers,
James
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp