Le 17/08/2016 à 17:28, Catalin Dominte a écrit :
I usually create a snmp filter to avoid polling interfaces ending in .0. If you poll an ex2200 / 3300 / 4200 it spends a long time polling the ifTable and ifxTable. The polling time is reduced considerably if .0 interfaces are dropped and I can poll the device every 5 minutes.
Yes snmp request can kill the control plane of EXs. For example Observium was killing my ex4550 (causing ldp sessions to drop and so on). I still consider that completely ridiculous...
With correct snmp filter the situation is less worse, but I still have to patch the Observium poller to let some breathes to my ex(s). OK the Observium poller is quite aggressive (or stupid depend of the point of view :).
What is everyone using to monitor their EX2200/VC stacks?
I've made some ugly scripts in python to check via ssh the output of "show virtual-chassis".
We are using check_mk to monitor our network which is great, however due to the way it polls or due to the low power of the ex2200 I'm unable to monitor all the individual interfaces.
Check-mk is great, but do lot of snmpwalk to check network devices. (If I had time I will take a look to patch and make it use an interfaces cache)
-- Raphael Mazelier _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp