Dear group, I am trying to establish a RSVP-OAM between a Juniper and Huawei device.
set protocols mpls label-switched-path Juniper-Huawei oam bfd-liveness-detection minimum-interval 100 set protocols mpls label-switched-path Juniper-Huawei oam bfd-liveness-detection multiplier 3 set protocols mpls label-switched-path Juniper-Huawei oam bfd-liveness-detection failure-action make-before-break teardown-timeout 10 set protocols mpls label-switched-path Juniper-Huawei link-protection set protocols mpls label-switched-path Juniper-Huawei adaptive set protocols mpls label-switched-path Juniper-Huawei to 1.1.1.2 Address State Interface Time Interval Multiplier 127.0.0.1 Down ae9.0 0.000 2.000 3 Client RSVP-OAM, TX interval 0.100, RX interval 0.100 Local diagnostic None, remote diagnostic None Remote state AdminDown, version 1 Session type: Multi hop BFD Min async interval 0.100, min slow interval 2.000 Adaptive async TX interval 2.000, RX interval 2.000 Local min TX interval 2.000, minimum RX interval 0.100, multiplier 3 Remote min TX interval 0.000, min RX interval 0.000, multiplier 0 Local discriminator 29, remote discriminator 0 Echo mode disabled/inactive, no-absorb, no-refresh LSP-Name Juniper-Huawei Session ID: 0x0 As Juniper is using 127.0.0.1 as a source address, it is not possible Huawei to understand this. Is there anyone who has an experience with MPLS OAM configuration between Juniper and other vendors like Cisco and Huawei? Is it possible to bring the session up from Juniper towards other vendors? Kind regards, Gokhan _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp