On Wed, Sep 01, 2021 at 09:44:08AM -0700, Mike via juniper-nsp wrote: > "Unified ISSU is supported with Junos OS Release 17.4R1 for MX Series > routers with MPC-3D-16XGE-SFPP" > > my expectations were that the card would stay online and there > would be little to no operational impact, but this clearly wasn't the > case. I am just wondering if anyone can tell me why this might have been > the case and in the future what steps I would need to take to ensure > this both otherwise stays on the air during a future software update?
Eventually during the ISSU process, the line card software needs to be upgraded. During that part, each line card goes offline one at a time. If you have multiple line cards, design your network such that redundant network paths are connected across different cards to prevent a total outage when each line card is upgraded one-by-one. _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp