revno: 1002
committer: John Frankland <[email protected]>
branch nick: 1.9
timestamp: Wed 2014-03-19 09:33:20 +0100
message:
  * Temporary calibration for CsI detectors on rings 1-9
  for Ta+Zn 39AMeV (simplified Parlog functional)
  
  - for Z>1, this is the 5th campaign calibration with gain parameter a1
    adjusted to fit data from E613.
    Uses fragments with Z=6,8,10,12 identified in Si-CsI maps.
    E_CsI calculated from dE_Si for dE_Si>5 MeV
    CsI with no calibrated Silicon detector are excluded,
    as are detectors 0106, 0108, 0403, 0624, 0711, 0712, 0916, 0919
    for which data did not permit a good fit with the simplified Parlog 
functional.
  - for Z=1, we took 5th campaign calib and applied same relative gain 
adjustment
    as for the Z>1 calibration
added:
  KVIndra/INDRA_e613/CsICalibZ1.dat
  KVIndra/INDRA_e613/CsICalibZ2.dat


--