https://bugs.kde.org/show_bug.cgi?id=521257
Bug ID: 521257
Summary: System monitor widget adds graphs for static data
strings
Classification: Plasma
Product: plasmashell
Version First 6.6.91
Reported In:
Platform: Arch Linux
OS: Linux
Status: REPORTED
Severity: minor
Priority: NOR
Component: System Monitor widgets
Assignee: [email protected]
Reporter: [email protected]
CC: [email protected], [email protected]
Target Milestone: 1.0
Created attachment 193013
--> https://bugs.kde.org/attachment.cgi?id=193013&action=edit
Demonstration of issue
STEPS TO REPRODUCE
1. Add a system monitor widget
2. Set it to grid mode
3. Add a "sensor" from the Operating System category, like Operating System
Name or KDE Plasma Version
OBSERVED RESULT
The widget attempts to draw graphs for those static strings of data and fails,
leaving it looking quite goofy.
EXPECTED RESULT
For those "sensors" to display at the bottom of the widget without graphs, or
be unavailable in this mode
SOFTWARE/OS VERSIONS
Operating System (available in the Info Center app, or by running `kinfo` in a
terminal window): Arch Linux
KDE Plasma Version: 6.6.91
KDE Frameworks Version: 6.26.0
Qt Version: 6.11.1
--
You are receiving this mail because: