https://bugs.kde.org/show_bug.cgi?id=442728

            Bug ID: 442728
           Summary: Data rate read/write does not work for md RAID devices
           Product: plasmashell
           Version: 5.22.4
          Platform: openSUSE RPMs
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: System Monitor
          Assignee: [email protected]
          Reporter: [email protected]
                CC: [email protected], [email protected]
  Target Milestone: 1.0

Monitoring hard disk data rate read/write works fine for individual hard disks
or NVMes, but if I try to monitor a soft raid (md device), the data rate is
always zero.
The interesting thing is that the data rate sensors of the hard disks that form
the md device (sda and sdb in my case) show correct values.

The behaviour is the same using ksysguard or the plasma widget.

The sensor's names in ksysguard are 
disk/mdXXX_(X:XXX)/Rate/rblk
disk/mdXXX_(X:XXX)/Rate/wblk

SOFTWARE/OS VERSIONS
Linux/KDE Plasma: openSUSE Tumbleweed 20210916
KDE Plasma Version: 5.22.5
KDE Frameworks Version: 5.86.0
Qt Version: 5.15.2

ADDITIONAL INFORMATION
Kernel 5.13.13

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to