https://bugs.kde.org/show_bug.cgi?id=447301

Nate Graham <n...@kde.org> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
          Component|general                     |Panel
            Summary|Hotkeys settings and        |Changes made to panel
                   |applets lost after sudden   |applets lost after sudden
                   |shutdown (due to empty      |shutdown (due to empty
                   |battery)                    |battery)
         Resolution|---                         |WAITINGFORINFO
             Status|REPORTED                    |NEEDSINFO

--- Comment #1 from Nate Graham <n...@kde.org> ---
These will be separate bugs, so let's use this one for panel applets, and use a
different one for changing hotkeys.

I cannot reproduce the issue by adding a Digital Clock applet to a Plasma Panel
and then *immediately* killing plasmashell with `killall -9 plasmashell` in a
terminal window. That's pretty much what an unexpected shutdown will do. Can
you reproduce the issue in this way?

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to