https://bugs.kde.org/show_bug.cgi?id=458038

            Bug ID: 458038
           Summary: Widgets become slightly misplaced (misaligned) after
                    login
           Product: plasmashell
           Version: 5.25.4
          Platform: Other
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: Desktop Containment
          Assignee: plasma-b...@kde.org
          Reporter: dcalv...@gmail.com
                CC: notm...@gmail.com
  Target Milestone: 1.0

Created attachment 151411
  --> https://bugs.kde.org/attachment.cgi?id=151411&action=edit
The yellow line shows the alignment position the widgets should have stayed
aligned to

SUMMARY
When logging in, right before the task manager panel appears at the bottom, all
the widgets shown on the screenshot are loaded first and they appear in their
right positions, as set previously before rebooting/relogin.
However right after the bottom task manager panel appears, they become
misplaced or misaligned, almost as if they would seem to "jump" out of
position.
This is on the third screen/display. All three displays are one next to the
other in an horizontal fashion, the widgets are placed in the one to my right
side.


STEPS TO REPRODUCE
1. Place widget to their desired positions.
2. Log off and login, or reboot and login.


OBSERVED RESULT
Observe the widgets become misplaced right after the bottom task manager is
loaded.

EXPECTED RESULT
The widgets remain in their specified position as they were placed before
rebooting.

SOFTWARE/OS VERSIONS
Operating System: Arch Linux
KDE Plasma Version: 5.25.4
KDE Frameworks Version: 5.97.0
Qt Version: 5.15.5
Kernel Version: 5.19.1-zen1-1-zen (64-bit)
Graphics Platform: X11
Processors: 12 × Intel® Core™ i7-8700K CPU @ 3.70GHz
Memory: 15.5 GiB of RAM
Graphics Processor: NVIDIA GeForce GTX 1070/PCIe/SSE2

ADDITIONAL INFORMATION
See screenshot. The yellow line shows the alignment position the widgets should
have stayed aligned to.
Also running 2 instances of conky for 2 information "panels".
The widgets that become misplaced are mainly "System Monitor" widgets, but I
also had this issue with an assortment of "Digital Clock" widgets that I had
previously placed on that same screen showing the time on different cities, and
the constant repositioning after a reboot required to make them useful was too
frustrating so I just removed them.
The widget's size is also slightly altered.

Could be related to "425368", though there's very little information on that