https://bugs.kde.org/show_bug.cgi?id=466907

            Bug ID: 466907
           Summary: System monitor settings pop-up cannot be dragged
    Classification: Plasma
           Product: plasma-systemmonitor
           Version: 5.27.2
          Platform: Other
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: general
          Assignee: ksysguard-b...@kde.org
          Reporter: david.cortes.riv...@gmail.com
                CC: ahiems...@heimr.nl, plasma-b...@kde.org
  Target Milestone: ---

SUMMARY
If I try to change the settings of something in the system monitor, the pop-up
window that it opens is not clickable, which is detrimental to usability as
then I cannot have a clear view of what I have currently configured to show in
the UI as I need to make changes.

STEPS TO REPRODUCE
1. Launch system monitor.
2. Go to some section like "Processes" in the left panel.
3. Click the three dots menu, select "Configure columns...".
4. Try to drag the pop-up that opens from its header section where there should
be a titlebar.

OBSERVED RESULT
Cannot drag the pop-up subwindow.

EXPECTED RESULT
Should let me drag the pop-up subwindow so that then I can see my current view
before as I change the settings.

SOFTWARE/OS VERSIONS
Operating System: Debian GNU/Linux 12
KDE Plasma Version: 5.27.2
KDE Frameworks Version: 5.103.0
Qt Version: 5.15.8
Kernel Version: 6.1.0-5-amd64 (64-bit)
Graphics Platform: X11
Processors: 20 × 12th Gen Intel® Core™ i7-12700H
Memory: 62.6 GiB of RAM
Graphics Processor: Mesa Intel® Graphics
Manufacturer: SLIMBOOK
Product Name: Executive

ADDITIONAL INFORMATION

-- 
You are receiving this mail because:
You are watching all bug changes.