https://bugs.kde.org/show_bug.cgi?id=482185
--- Comment #9 from Ye Jingchen <[email protected]> --- (In reply to revinary from comment #8) > I experience this bug as well under Plasma 6.0.2 and Qt 6.6.2 on Arch Linux. > > Regular panel (vertical, not floating, no auto-hide) containing "Application > Menu", "Icon-Only Task Manager", "System Tray" and "Digital Clock". > Context menus of the task and tray icons work correctly. > Context menus of the app menu, task manager and clock show as top-level > windows in the middle of the screen. > > When the Application Menu is open the button's context menu works correclty. In my experience, a window need to be focused to trigger this bug. Opening application window changes the focus to application menu itself, thus bypassing the issue. > > In my case there is no screen (un)locking involved. > Simply power cycling my DP monitor does not trigger the bug, either. > In addition, after the power cycle I need to open a context menu in another > application first (Vivaldi in my case, menu shows correctly) and then the > bug manifests for plasmashell context menus. -- You are receiving this mail because: You are watching all bug changes.