https://bugs.kde.org/show_bug.cgi?id=488908
Bug ID: 488908
Summary: System monitor widget with vertical bar graph does not
scale graphs properly
Classification: Plasma
Product: plasmashell
Version: 6.1.0
Platform: Arch Linux
OS: Linux
Status: REPORTED
Severity: normal
Priority: NOR
Component: System Monitor
Assignee: [email protected]
Reporter: [email protected]
CC: [email protected], [email protected]
Target Milestone: 1.0
Created attachment 170764
--> https://bugs.kde.org/attachment.cgi?id=170764&action=edit
On the left I have only cpu usage sensor, which depicts some value. On the
right I have the same cpu usage sensor with physical memory, swap and vram
used, where it does not show up
SUMMARY
When multiple sensors are used, system monitor widget's vertical bar graph does
not scale the values with automatic data range option enabled.
STEPS TO REPRODUCE
1. Add system monitor widget to tray
2. Add CPU used, Physical memory used (Bytes not percentage i.e. different
units) to sensors list
OBSERVED RESULT
The CPU usage graph does not show up at all compared to the RAM value
EXPECTED RESULT
All sensor values should be scaled according to their own maximum value, 100
for percentages, maximum RAM available for physical memory used
SOFTWARE/OS VERSIONS
Linux/KDE Plasma: Kernel: 6.9.5.arch1-1
(available in About System)
KDE Plasma Version: 6.1.0
KDE Frameworks Version: 6.3.0
Qt Version: 6.7.1
ADDITIONAL INFORMATION
This issue does not occur when either only one sensor is used or horizontal bar
graph is selected.
--
You are receiving this mail because:
You are watching all bug changes.