https://bugs.kde.org/show_bug.cgi?id=493164
Bug ID: 493164
Summary: plasma-systemmonitor shows an exaggerated number
(possibly plugged from top?)
Classification: Applications
Product: plasma-systemmonitor
Version: 6.0.5
Platform: NixOS
OS: Linux
Status: REPORTED
Severity: minor
Priority: NOR
Component: general
Assignee: [email protected]
Reporter: [email protected]
CC: [email protected], [email protected]
Target Milestone: ---
Created attachment 173692
--> https://bugs.kde.org/attachment.cgi?id=173692&action=edit
3 Windows showing different system monitors, on the bottom left is top, on the
top left its htop and the right its plasma-systemmonitor
plasma-systemmonitor shows an exaggerated ram usage after using the system for
a while
1. Start Plasma6
2. Use the system normally or idly
3. Measure high ram usage despite 2.
OBSERVED RESULT
The system monitor is reporting a false number that shows the ram usage
climbing as system is being used, this is the same number reported by top but
not reported by htop/btop
EXPECTED RESULT
It should show a realistic number going in line with system monitors like
htop/btop and not an exaggerated number
SOFTWARE/OS VERSIONS
Operating System: NixOS 24.05
KDE Plasma Version: 6.0.5
KDE Frameworks Version: 6.2.0
Qt Version: 6.7.2
Kernel Version: 6.6.51 (64-bit)
Graphics Platform: Wayland
Processors: 4 × 11th Gen Intel® Core™ i3-1115G4 @ 3.00GHz
Memory: 15.4 GiB of RAM
Graphics Processor: Mesa Intel® UHD Graphics
--
You are receiving this mail because:
You are watching all bug changes.