https://bugs.kde.org/show_bug.cgi?id=492436
Niccolò Venerandi <[email protected]> changed: What |Removed |Added ---------------------------------------------------------------------------- Status|ASSIGNED |RESOLVED Resolution|--- |FIXED Latest Commit| |https://invent.kde.org/plas | |ma/libplasma/-/commit/a4711 | |3c9657cbc62b05d02963d212280 | |2281805f Version Fixed In| |6.2.0 --- Comment #5 from Niccolò Venerandi <[email protected]> --- Git commit a47113c9657cbc62b05d02963d2122802281805f by Niccolò Venerandi. Committed on 18/09/2024 at 15:26. Pushed by niccolove into branch 'master'. Handle floating point position and size for PlasmoidHeading logic It seems like the x position of the digital clock PlasmoidHeading is 2e-23 (I did not see why it assumed that value, maybe has to do with fractional scaling?); and, the size is also a fraction short of the window width. Just for sure, I add here some logic to add with non-integer position and sizes, since the rounded corners depend on it. FIXED-IN: 6.2.0 M +2 -2 src/declarativeimports/plasmaextracomponents/qml/PlasmoidHeading.qml https://invent.kde.org/plasma/libplasma/-/commit/a47113c9657cbc62b05d02963d2122802281805f -- You are receiving this mail because: You are watching all bug changes.