** Changed in: linux (Ubuntu Xenial)
Status: In Progress => Fix Committed
--
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1607387
Title:
lm-sensors is throwing "ERROR: Can't get value of subfeature
temp1_input: I/O error" for be2net driver
Status in linux package in Ubuntu:
Fix Released
Status in linux source package in Xenial:
Fix Committed
Bug description:
== Comment: #17 - Guilherme Guaglianoni Piccoli - 2016-07-27 18:49:08 ==
Temperature and fan information from hardware are normally available to
userspace through hwmon sysfs abstraction. In case of be2net driver, all PCI
devices "managed" by this driver have hwmon entries, which are filled in a
delayed workqueue on driver, every 64 seconds.
The issue we're seeing is that the hardware temperature queries to
devices' fw are performed only in devices which interface is up - so,
we end up having messages like below when using the "sensors" tool
(from lm-sensors), for example:
be2net-pci-50100
Adapter: PCI adapter
ERROR: Can't get value of subfeature temp1_input: I/O error
temp1: N/A
The following upstream commit addresses this issue:
d3480615cf ("be2net: perform temperature query in adapter regardless of its
interface state")
[https://git.kernel.org/cgit/linux/kernel/git/powerpc/linux.git/commit/?id=d3480615cf00c6f615cdb61a9d03386574b93342]
We would like Canonical to merge this commit in the Xenial kernel.
Thanks in advance,
Guilherme
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1607387/+subscriptions
--
Mailing list: https://launchpad.net/~kernel-packages
Post to : [email protected]
Unsubscribe : https://launchpad.net/~kernel-packages
More help : https://help.launchpad.net/ListHelp