Grace,

I tried the latest gnome-shell 3.34.1 on 5.2.0 kernel, this issue is
fixed. So I thought the upstream already met this issue before.

I will need more time to find the root cause and patches.

It's a little hard to have a target date for me to resolve this issue,
it also depends the people from the ubuntu desktop team, I will do my
best and hope find related patches at this week.

Thanks!

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux-meta-oem in Ubuntu.
https://bugs.launchpad.net/bugs/1850886

Title:
  Auto-rotate is not working properly when system is booted up while not
  in its regular orientation

Status in GNOME Shell:
  New
Status in linux-meta-oem package in Ubuntu:
  Confirmed

Bug description:
  [RELEASE VERSION]
  Description:  Ubuntu 18.04.3 LTS
  Release:      18.04

  [PACKAGE VERSION]
  linux-oem:
    Installed: 4.15.0.1057.61
    Candidate: 4.15.0.1057.61
    Version table:
   *** 4.15.0.1057.61 500
          500 http://jp.archive.ubuntu.com/ubuntu bionic-updates/main amd64 
Packages
          500 http://security.ubuntu.com/ubuntu bionic-security/main amd64 
Packages
          100 /var/lib/dpkg/status
       4.15.0.1004.2 500
          500 http://jp.archive.ubuntu.com/ubuntu bionic/main amd64 Packages

  [EXPECTED OUTPUT]
  Upon boot up with auto-rotation enabled, display should show the proper 
screen orientation of the system accordingly

  [ACTUAL OUTPUT]
  Auto-rotation is not working properly when system is booted up while not in 
its regular orientation

  [STEPS]
  1. Make sure auto-rotation is enabled on the system
  2. Before turning the system on, put it on tablet mode, with the inverted 
landscape rotation (the top part/the part with the camera is adjacent to the 
surface). The system should follow this orientation when the login screen 
appears.
  3. Login to the system
  4. Switch to the clam shell mode. The display suddenly becomes inverted/the 
opposite direction of the expected output.
  5. Switch back to the tablet mode. The display also ends up being inverted/in 
the opposite direction of the expected output

  [REMARKS]
  *Using WHL
  *The system seems to be setting the orientation according to the orientation 
during boot up

  ProblemType: Bug
  DistroRelease: Ubuntu 18.04
  Package: linux-oem 4.15.0.1057.61
  ProcVersionSignature: Ubuntu 5.0.0-1024.27-oem-osp1 5.0.21
  Uname: Linux 5.0.0-1024-oem-osp1 x86_64
  ApportVersion: 2.20.9-0ubuntu7.7
  Architecture: amd64
  CurrentDesktop: ubuntu:GNOME
  Date: Fri Nov  1 14:23:14 2019
  DistributionChannelDescriptor:
   # This is the distribution channel descriptor for the OEM CDs
   # For more information see 
http://wiki.ubuntu.com/DistributionChannelDescriptor
   
canonical-oem-sutton-bionic-amd64-20190722-12+sutton-dijkstra-bionic-amd64+iso
  InstallationDate: Installed on 2019-07-25 (98 days ago)
  InstallationMedia: Ubuntu 18.04 "Bionic" - Build amd64 LIVE Binary 
20190722-05:40
  SourcePackage: linux-meta-oem
  UpgradeStatus: No upgrade log present (probably fresh install)

To manage notifications about this bug go to:
https://bugs.launchpad.net/gnome-shell/+bug/1850886/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to     : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to