Hello,

using 5.15.0-1019-bluefield, we see the tuples were offloaded and we
also see the offload entries.

Thanks

** Tags removed: verification-needed-jammy
** Tags added: verification-done-jammy

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux-bluefield in Ubuntu.
https://bugs.launchpad.net/bugs/2012571

Title:
  net/sched: cls_api: Support hardware miss to tc action

Status in linux-bluefield package in Ubuntu:
  Invalid
Status in linux-bluefield source package in Focal:
  Fix Released
Status in linux-bluefield source package in Jammy:
  Fix Committed

Bug description:
  * Explain the bug(s)
   
  Currently tc miss interface only supports resuming from a specific tc chain.
  If a packet modification is done before a missable action such as CT and
  there is a miss in CT after it, this may cause a miss match when resuming
  re-executing the same chain in software, and wrong packet count.
  This use case for example is a stateless (static) nat.
   
  * brief explanation of fixes
   
  Add support for missing to a specific action instance, and support
  of per action hardware stats to update what was actually done in hardware.
   
  * How to test
   
  Create OVS bridge with 2 devices mlx5 rep devices.
  Enable HW offload and configure regular connection tracking OpenFlow rules
  with packet modification before the CT action (such as statless nat):

   
  e.g:

      ovs-ofctl del-flows br-ovs
      ovs-ofctl add-flow br-ovs arp,actions=normal
     ovs-ofctl add-flow br-ovs "in_port=1,table=0, ip,ct_state=-trk 
actions=mod_nw_dst=1.1.1.2,ct(table=1)"
      ovs-ofctl add-flow br-ovs "in_port=1,table=1, ip,ct_state=+trk+new 
actions=ct(commit),output:2"
      ovs-ofctl add-flow br-ovs "in_port=1,table=1, ip,ct_state=+trk+est, 
actions=output:2"
      ovs-ofctl add-flow br-ovs "in_port=2,table=0, ip,ct_state=-trk 
actions=ct(table=1)"
      ovs-ofctl add-flow br-ovs "in_port=2,table=1, ip,ct_state=+trk+est, 
actions=mod_nw_src=1.1.1.2,output:1"

   
  Config VF1 ip 1.1.1.1, VF2 ip 1.1.1.2

  For VF2, add route and static neighbour to floating (router) ip
  5.5.5.5

  
  Then run a TCP connection, e.g:

  on mlx5 VF1 iperf -s                           #(which will listen on 1.1.1.2)
  on mlx5 VF2 iperf -c 5.5.5.5 -t 10    #(this creates a packet from 1.1.1.1 -> 
5.5.5.5, and nat will change this to 1.1.1.1->1.1.1.2)

  
  Optional: In different terminal, while traffic is running, check for offload:
  tcpdump -nnepi <RELEVANT_MLX5_REP> tcp
  and see no iperf tcp packets.

  Dump conntrack with relevant ip:
  cat /proc/net/nf_conntrack | grep -i  1.1.1.1

  See tuples were offloaded:
  ipv4     2 tcp      6 src= 1.1.1.1 dst=1.1.1.2 sport=56394 dport=5001 
packets=2 bytes=112 src=1.1.1.2 dst=1.1.1.1 sport=5001 dport=56394 packets=1777 
bytes=665340 [HW_OFFLOAD] mark=0 zone=0 use=3

  
  * What it could break.
  offload for modifications + ct and tc packet count.

To manage notifications about this bug go to: