On 10/8/2014 7:54 AM, joaoandrefe...@sapo.pt wrote: > Citando joaoandrefe...@sapo.pt: > >> Citando Frank Rowand <frowand.l...@gmail.com>:
< snip > >>>> Host window #2 (minicom): >> >> $ minicom -o -w -p /dev/pts/1 Welcome to minicom 2.3 >> >> OPTIONS: I18n Compiled on Aug 19 2010, 05:48:57. Port /dev/ttyS0 >> >> Press CTRL-A Z for help on special keys >> >> >> So, it seems minicom is initialized correctly, however despite >> seeing the cursor of the terminal, if I try to insert commands on >> it nothing will change / happen (I can't even see the commands I'm >> trying to type appearing in the screen). Pressing CTRL+A Z brings >> me the menu with options, but after trying almost all of them and >> searching for minicom tutorials online, I'm not progressing on >> this. Sorry for this (another) rookie doubt, I'm also on a race >> against time but I can't seem to figure this out. > > (Some kind of) update on the minicom part: I found people with a > similar problem, here: > http://ubuntuforums.org/showthread.php?t=1112330. However, even after > applying the changes mentioned there (changing hardware and software > flow control settings, under the "serial port setup" option, I'm > still unable to write anything on the console. I've tried with > hardware as "no" and software as "no", but also hardware as "no" and The serial port setup would matter if you attached minicom directly to the serial port. But since you attach to a pty with "-p /dev/pts/1" it should not matter. > software as "yes". I even changed the serial device from "/dev/ttyS0" > to "/dev/pts/1", tried the same flow control settings combinations, > with no success. However, one thing I've noticed in that thread is > that people who are complaining about the same issue have some kind > of automatic message (for instance "AT S7=45 S0=0 L1 V1 X4 &c1 E1 > Q0") printed in the console. I don't have that, as can be seen in the > output above. Also, the text on the green bar at tyhe bottom of the The minicom "-o" option tells it not to initialize, so it does not send the "Init string" (the "At S7=45 S0=0...") when you run minicom. CTRL-A Z O (configuration) Modem and dialing will show you the automatic message (in this case, the "Init string"). These are the old "AT" modem commands which tells a modem what to do. > console says I'm offline, which of course must be related (in detail, > it says "CTRL-A Z for help |115200 8N1 | NOR | Minicom 2.3 | VT102 > | Offline"). I'll be searching more on this and let you know any > improvement. Thanks. My minicom status bar shows: CTRL-A Z for help |115200 8N1 | NOR | Minicom 2.5 | VT102 | Offline ------------------------------------------------------------------------------ Meet PCI DSS 3.0 Compliance Requirements with EventLog Analyzer Achieve PCI DSS 3.0 Compliant Status with Out-of-the-box PCI DSS Reports Are you Audit-Ready for PCI DSS 3.0 Compliance? Download White paper Comply to PCI DSS 3.0 Requirement 10 and 11.5 with EventLog Analyzer http://pubads.g.doubleclick.net/gampad/clk?id=154622311&iu=/4140/ostg.clktrk _______________________________________________ Kgdb-bugreport mailing list Kgdb-bugreport@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/kgdb-bugreport