On 8/31/2011 2:12 AM, jean-pierre charras wrote: > Le 30/08/2011 21:44, Wayne Stambaugh a écrit : >> I was looking over open bug reports a while back and ran across this report: >> https://bugs.launchpad.net/kicad/+bug/593782. While technically not a bug, I >> can understand why a user would be confused by this. Should we prevent >> duplicate sheet names? In the future it may be a problem as I am trying to >> avoid using the current time stamp solution to hierarchical schematic designs >> in the new schematic file format for readability reasons. Anyone else have >> any >> thoughts on this? >> >> Wayne >> > > I believe we should not accept duplicate sheet names. > Yes this is confusing, and duplicate sheet names are a potential source of > bugs. >
JP, Thanks for the reply. I already have a patch to prevent the user from entering duplicate sheet names on a schematic page. However, it doesn't address the case where schematics already have duplicate sheet names. I'll commit the changes that I have and take a look at what can be done for existing schematics. Wayne _______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : [email protected] Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp