Since my recent change to hide dangling ends also responds to no-connect markers, SCH_NO_CONNECT should be changed to correctly update dangling ends after it is placed. This patch accomplishes that.
-- Chris
commit 32d30d6b24bc75bdfa300153d5e4430a15234456 Author: Chris Pavlina <[email protected]> Date: Mon Jun 22 11:23:50 2015 -0400 Update dangling ends when adding no-connect diff --git a/eeschema/bus-wire-junction.cpp b/eeschema/bus-wire-junction.cpp index 62141bd..a33f7b5 100644 --- a/eeschema/bus-wire-junction.cpp +++ b/eeschema/bus-wire-junction.cpp @@ -379,14 +379,10 @@ SCH_NO_CONNECT* SCH_EDIT_FRAME::AddNoConnect( wxDC* aDC, const wxPoint& aPositio SCH_NO_CONNECT* no_connect = new SCH_NO_CONNECT( aPosition ); SetRepeatItem( no_connect ); - - m_canvas->CrossHairOff( aDC ); // Erase schematic cursor - no_connect->Draw( m_canvas, aDC, wxPoint( 0, 0 ), GR_DEFAULT_DRAWMODE ); - - m_canvas->CrossHairOn( aDC ); // Display schematic cursor - GetScreen()->Append( no_connect ); + GetScreen()->SchematicCleanUp( m_canvas, aDC ); OnModify(); + m_canvas->Refresh(); SaveCopyInUndoList( no_connect, UR_NEW ); return no_connect; }
_______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : [email protected] Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp