Urgh, patch attached here. On Wed, Feb 8, 2017 at 11:04 PM, Oliver Walters < [email protected]> wrote:
> I have amended the patch to only ignore connection of pins that are both > INVISIBLE and NC (Electrical Type = Not Connected). This will improve the > safety of the current libraries which do contain many parts with NC pins > set as invisible. > > It will also NOT change the behaviour of people using invisible pins for > one-to-many connection. > > Thoughts? > > On Tue, Feb 7, 2017 at 7:47 PM, Oliver Walters < > [email protected]> wrote: > >> Hi all, >> >> The attached patch prevents invisible pins from being connected using the >> wire tool in eeschema. >> >> a) If you connect a wire endpoint to the same position as a pin endpoint, >> they are NOT connected visually >> b) Wires and insivible pins are also ignored during netlist creation >> c) This does not affect the ability of invisible power-pins to >> automatically connect to global power labels >> >> Is the current behavior of connecting invisible pins to wire endpoints >> desired? Or is it just an aberration? >> >> If there is a very good reason that pins not visible in the schematic are >> able to be connected silently? >> >> before: http://i.imgur.com/3gModvW.png >> >> after: http://i.imgur.com/r8O7c3Y.png >> >> (Note the 'dangling' wire-end indication) >> >> Cheers, >> Oliver >> >> >> >
invisi-pin-fix-2.patch