old thread, but I think it's relevant to my issue. My interest is mostly in the python interface to pcbnew.[0]
With the new connectivity stuff, what's the proper way to ask a net what pads belong to it? In python, I used to be able to do net.Pads() [1] I tried adding connectivity.h[2] to boards.i via a new connectivity.i but then I realized that GetConnectedPads can't take a net. net is not a board_connected_item I could iterate through all pads and compare each one's net. Seems like a not so good way to do it. I do see that the implementation of GetPadCount(aNet) does just that.[3] Also, in that implementation, it's referencing connAlgo's padList. Is this better than asking board for its pads? I'm thinking the whole "don't repeat yourself" thing [4] So, what is the recommended way to get a net's list of pads? Miles [0] my tutorials are referenced from kicad's tutorials list http://kicad-pcb.org/help/tutorials/ -> https://kicad.mmccoo.com/kicad-scripting-table-of-contents/ [1]: removed with this checkin: Author: Tomasz Włostowski <[email protected]> 2017-03-22 14:51:07 Committer: Tomasz Włostowski <[email protected]> 2017-06-23 11:12:37 Parent: 8b59350e44a9894f02977ae26da166b239ef7da3 (Pcbnew: fix override release build error.) Child: 75cda5021d72011f2de54cadbca32581a5319fa9 (Assure that NETINFO_ITEMs have a NETCLASS object assigned) Branches: master, remotes/origin/master Follows: 4.0.0-rc2 Precedes: Removed legacy connectivity/ratsnest algorithm, replaced with the new one. No legacy autorouting for the moment [2]: shouldn't this be called class_connectivity_data.h? [3] here's GetPadCount unsigned int CONNECTIVITY_DATA::GetPadCount( int aNet ) const { int n = 0; for( auto pad : m_connAlgo->PadList() ) { if( !pad->Valid() ) continue; auto dpad = static_cast<D_PAD*>( pad->Parent() ); if( aNet < 0 || aNet == dpad->GetNetCode() ) { n++; } } return n; } [4] https://en.wikipedia.org/wiki/Don%27t_repeat_yourself <https://en.wikipedia.org/wiki/Don%27t_repeat_yourself> On Mon, Jul 3, 2017 at 11:47 AM, Kristoffer Ödmark < [email protected]> wrote: > Hey Tom! > > Any ETA for the new Via tool dialog? It's some solid work you have done, > thanks! > > - Kristoffer > > > On 2017-06-27 21:54, Tomasz Wlostowski wrote: > >> On 27.06.2017 21:24, Simon Küppers wrote: >> >>> Small Bump. >>> >>> Can anyone shed some light on the new Via Tool? Is it supposed to be not >>> ready yet? The Track & Via Properties Dialog looks really unfinished and >>> I cannot modify anything beside Position and Via Size there. Is it >>> because I am using the Cairo Canvas? >>> >>> Sorry, I forgot that I left the dialog unfinished. Will fix in a couple >> of days... >> >> Tom >> >> _______________________________________________ >> Mailing list: https://launchpad.net/~kicad-developers >> Post to : [email protected] >> Unsubscribe : https://launchpad.net/~kicad-developers >> More help : https://help.launchpad.net/ListHelp >> >> > _______________________________________________ > Mailing list: https://launchpad.net/~kicad-developers > Post to : [email protected] > Unsubscribe : https://launchpad.net/~kicad-developers > More help : https://help.launchpad.net/ListHelp >
_______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : [email protected] Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp