Gave this a shot, I like this logic, thanks! On Thu, Nov 30, 2017 at 8:55 PM, Seth Hillbrand <seth.hillbr...@gmail.com> wrote:
> Attached is a patch to correct the wire/bus connection logic. Currently, > Eeschema will register wires and busses as being connected if their > endpoints touch. They will drag together and their endpoints will not show > the "unconnected" symbols. > > The attached patch implements the following logic. The logic is largely > based on how I like to work with entries, so please shout if you feel this > is backwards somehow. > > Dragging: > - busses and bus-bus entries drag each other when connected at > endpoints > - wires and wire-bus entries drag each other when connected at > endpoints > - entries do not drag wires or busses when connected to wire middles > - wire-bus entries do not drag busses > > Connections: > - bus-bus entries connect busses to busses but not wires > - wire-bus entries connect wires to busses but not wire to wires or > busses to busses > > Best- > Seth > > > _______________________________________________ > Mailing list: https://launchpad.net/~kicad-developers > Post to : kicad-developers@lists.launchpad.net > Unsubscribe : https://launchpad.net/~kicad-developers > More help : https://help.launchpad.net/ListHelp > >
_______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : kicad-developers@lists.launchpad.net Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp