Seth, I merged your patch.
Thanks, Wayne On 12/15/2017 01:15 PM, Seth Hillbrand wrote: > The attached patch adjusts how dangling ends are shown for wire-bus > entries to correct the behavior Nick reported. > > Previously, wire-bus entries were shown as dangling if there was a wire > or a bus at both ends. This broke in the case of the Coldfire demo > where a bus was drawn over a wire and there was also an entry point (see > attached image coldfire-broken.png). > > The patch implements the logic that if there is _at least_ a wire and a > bus at each end, that the entry is considered not dangling. (see > attached image coldfire-fixed.png) > > -Seth > > > > _______________________________________________ > Mailing list: https://launchpad.net/~kicad-developers > Post to : [email protected] > Unsubscribe : https://launchpad.net/~kicad-developers > More help : https://help.launchpad.net/ListHelp > _______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : [email protected] Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp