For V5, the color issue would have to be resolved in a different way than I was proposing, since the connectivity information won't be there.
I think it might be best to hold off on this patch until after V6 development is open since it is not a major bug fix and it would be prudent to do a fair amount of testing that this doesn't impact netlisting. -Jon On Wed, Dec 20, 2017 at 10:24 AM, Wayne Stambaugh <[email protected]> wrote: > What is the probability that this breaks any existing schematics and how > soon could the color issue be resolved? If the risk of breaking > existing schematics is very low and the color issue can be resolved > reasonably soon, then I would consider merging for the stable 5 version. > Otherwise, we should hold off until the we open version 6 for development. > > Cheers, > > Wayne > > On 12/20/2017 8:34 AM, Jon Evans wrote: > > This patch is essential for my connectivity work (but that's not a V5 > > thing...) > > It would be quite easy for me to implement the color thing as part of > > the connectivity changes (since the junction would be able to know if it > > was connected to buses or not) > > > > -Jon > > > > On Wed, Dec 20, 2017 at 8:18 AM, Wayne Stambaugh <[email protected] > > <mailto:[email protected]>> wrote: > > > > Seth, > > > > Technically this is a new feature since KiCad has never used junction > > indicators on buses in the past so I'm hesitant to merge this for > > version 5. I do like the dragging of buses that this patch provides. > > I'm also thinking that the bus junction color should be the same > color > > as the bus color rather than the wire color but that may be difficult > > given our coloring scheme for schematic objects. Does anyone else > have > > any opinions on this patch? > > > > Cheers, > > > > Wayne > > > > > > On 12/14/2017 6:24 PM, Seth Hillbrand wrote: > > > The attached patch adds junction management to buses in addition > > to wires. > > > > > > Of note, this also adds buses to the draggable junctions > collection. > > > Now that junctions are managed internally, it makes sense to allow > any > > > collection with a junction to allow draggable junctions. > > > > > > -Seth > > > > > > > > > _______________________________________________ > > > Mailing list: https://launchpad.net/~kicad-developers > > <https://launchpad.net/~kicad-developers> > > > Post to : [email protected] > > <mailto:[email protected]> > > > Unsubscribe : https://launchpad.net/~kicad-developers > > <https://launchpad.net/~kicad-developers> > > > More help : https://help.launchpad.net/ListHelp > > <https://help.launchpad.net/ListHelp> > > > > > > > _______________________________________________ > > Mailing list: https://launchpad.net/~kicad-developers > > <https://launchpad.net/~kicad-developers> > > Post to : [email protected] > > <mailto:[email protected]> > > Unsubscribe : https://launchpad.net/~kicad-developers > > <https://launchpad.net/~kicad-developers> > > More help : https://help.launchpad.net/ListHelp > > <https://help.launchpad.net/ListHelp> > > > > >
_______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : [email protected] Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp