Le 07/01/2018 à 19:34, Andrey Kuznetsov a écrit :
> Should kicad not impose 2 layer restrictions on blind/buried vias? That way 
> users could at least use
> them, but will have to manually be careful since DRC doesn't support it. 
> There could be 2
> blind/buried vias on top of each other vertically, but on different layers 
> and not touching.
> And have unlimited adjacent layer selection, from<->to.
> 

There are no restriction for blind/buried vias.
Just the DRC does not test for valid layers pairs, because there are no layer 
stackup manager in
Pcbnew, and therefore the user cannot define constraints for blind/buried vias.


-- 
Jean-Pierre CHARRAS