Hi David,

I suggest you use a "No Connect Flag" to those un-used pins. This will
not generate any error when you run DRC (PCB) or ERC (SCH).

I understand what you mean, you can create your own schematic library
using the library editor to create your own set or customized
component but be sure to place a footprint to link your component to PCB.

I hope this helps.

Cheers
Harold

--- In [email protected], "David Bourgeois" <[EMAIL PROTECTED]> wrote:
>
> Hi all,
> 
> I'm creating new components for eeschema and have 2 questions.
> 
> 1. How should I handle 'NC' (not connected) pins of my component? If
I add  
> them, the ERC checks for a connection, even if 'No Draw' is active.
Should  
> I simply not place them?
> 
> 2. Many IC's have 2 or more alternatives depending on the packaging.
The  
> ATMega88 has different pinouts in PDIP and SMD packages. The
component is  
> even different as a couple of pins (ADC6, ADC7) are only available
in the  
> SMD versions. Should I create 2 different components? It seems the 'De  
> Morgan convert' stuff is close to what I need but is not really made
for  
> that purpose, and would only allow 2 different views anyway which
won't be  
> enough for some components.
> 
> Thanks,
> David Bourgeois
>


Reply via email to