Hi David, I suggest you use a "No Connect Flag" to those un-used pins. This will not generate any error when you run DRC (PCB) or ERC (SCH).
I understand what you mean, you can create your own schematic library using the library editor to create your own set or customized component but be sure to place a footprint to link your component to PCB. I hope this helps. Cheers Harold --- In [email protected], "David Bourgeois" <[EMAIL PROTECTED]> wrote: > > Hi all, > > I'm creating new components for eeschema and have 2 questions. > > 1. How should I handle 'NC' (not connected) pins of my component? If I add > them, the ERC checks for a connection, even if 'No Draw' is active. Should > I simply not place them? > > 2. Many IC's have 2 or more alternatives depending on the packaging. The > ATMega88 has different pinouts in PDIP and SMD packages. The component is > even different as a couple of pins (ADC6, ADC7) are only available in the > SMD versions. Should I create 2 different components? It seems the 'De > Morgan convert' stuff is close to what I need but is not really made for > that purpose, and would only allow 2 different views anyway which won't be > enough for some components. > > Thanks, > David Bourgeois >