--- In [email protected], "glinelec" <[EMAIL PROTECTED]> wrote: > > My EeSchima seems to have stopped allowing wire placements. > If I select the add wire button the bottom right status shows Add Wire. > When I click on a pin the status shows Block Move and the operation > switches to block move even though the Add Wire button is "depressed". > I am have been using the system for a while and have not experienced > this before. > Same occurs with add bus but not with add component or add powers. > Any ideas what I am doing wrong? > Version is 19 11 2007 Windows. >
Try this: 1) Make sure you have a relatively course grid setting, say like 50 mils for this test. 2) Always release the mouse button after clicking it, and BEFORE moving the mouse to extend the wire. Let us know if this makes a difference. At or near the new year we made a change that causes some of these actions to trigger on mouse release rather than mouse down. I think block select is the exception, and this may be the explanation. Dick Hollenbeck SoftPLC Corporation http://softplc.com